• m1
  • m2
  • m3
  • m4
  • m5
m11 m22 m33 m44 m55
 
 
 

Fluidic Devices Analog & Digital
(Closed circuit System)


A. FLUIDIC DEVICES ANALOG


Glass Tube Type Rotameter.
Range : 4.2 - 42 LPM.
Size : 1”.
Fluid : Water.

Magnetic Flow Meter.
Size : 1”.
Fluid : Water.
End Connections : Screwed/Flanged.

Turbine Flow Meter
Fluid : Water.
End Connections : Screwed/Flanged.

Orifice Meter
Size : 1”.
End Contact : Screwed.
Material : Gun Metal.

Venturemeter
Size : 1”.
End Connections : Screwed.
Material : LGM

Nozzle Meter :
Size : 1”.

U-Tube Manometer with drain & air valves Ht 1 m.

Water Supply Unit for above meters ½ HP pumpset, water pump - 300 Ltr .
Measuring tank of 100 Ltr. capacity necessary pipe fittings, valve, M.S. stand, valve, fittings, mountings, electrical connections, switches will be provided.
 
 
B. FLUIDIC DEVICES DIGITAL
 

i) FLOW MEASUREMENT BY ELECTRONIC DIFFERENTIAL PRESSURE FLOW TRANSMITTER

The setup consists of

Electronic Differential Pressure flow Transmitter :

Input : 0 to 2500 mm of wc
Output : 4 to 20 mA.
Supply : 24 VDC

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : ½ HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No.

ii) FLOW MEASUREMENT BY ULTRASONIC FLOW METER

The setup consists of

Ultrasonic Flow Transmitter
Input : 0 to 300 mm of wc in open channel
Output : 4 to 20 mA.
Supply : 24 VDC

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : ½ HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No.

iii) FLOW MEASUREMENT BY ELECTROMAGNETIC FLOW METER


The setup :

Electromagnetic Flow Transmitter
Input : 0 to 150 lpm
Output : 4 to 20 mA
Supply : 24 VDC
Line size : 1” BSP

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : ½ HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No.


iv) FLOW MEASUREMENT BY OPTICAL FLOW TRANSMITTER
(Turbine Type)

The Set Up Consist of :

Optical Flow Transmitter
Input : 4 to 40 lpm
Output : 4 to 20 mA
Line size : 1” BSP
Supply : 24 VDC.

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : ½ HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No.


v) FLOW MEASUREMENT BY VORTEX FLOW METER

The Set Up Consist of :

Vortex Flow Transmitter :
Input : 0 to 150 lpm.
Out put : 4 to 20mA
Supply : 24 VDC.
Mounting : Field by DC

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : ½ HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No


vi) FLOW MEASUREMENT BY MASS FLOW METER

The Set Up Consist of :

Mass Flow Transmitter :
Input : 0 to 400 lpm.
Out put : 4 to 20mA
Supply : 24 VDC.
Line size : 1” BSP
Mounting : Inline field type.

Digital Flow indicator. ( 3 ½ digit)

Measuring Tank : 80 litre.

Water sump : 120 litre.

Pump : 1 HP for water circulation

M. S. pipe structure for mounting all above

Instruction manual. 1 No

 

 
Flow Measurement by Ultra Sonic Flow Meter
 

The unit consist of :

Ultrasonic Flow transmitter
Range : 0 to 100 lpm
Output : 4 to 20 mA
Mounting : Field type
Supply : 24 VDC.
Accuracy : + 1%

Water Sump :
Capacity : 150 litre
Drain Valve : 1 No.
Material of Construction : CRC with powder coating.

Flow Channel :
Material of construction : CRC with powder coating.

Measuring Tank
Capacity : 80 liter
Drain valve : 2”
Material construction : CTC. With powder coatin

Pump : for water circulation : ½ HP.

Electronic Digital Flow Indicator : 3 ½ digit.

Power supply : 24 VDC.

Stand : Sturdy M. S. stand mounting all above tanks.

Instruction Manual : 1 copy

 
 

 
Level Measurement by Ultra Sonic Level Meter
 

The unit consist of :

Ultrasonic Level transmitter
Range : 0 to 500mm of wc

Water Sump :
Capacity : 150 litre
Drain Valve : 1 No.
Material of Construction : CRC with powder coating.

Level Tank :
Size : 400 x 400 x 600 material of construction : CRC with powder
coating.

Measuring Tank :
Capacity : 80 liter
Drain valve : 2”
Material construction : CTC. With powder coatin

Pump : for water circulation : ½ HP.

Electronic Digital Level Indicator : 3 ½ digit.

Power supply : 24 VDC.

Stand : Sturdy M. S. stand mounting all above tanks.

Instruction Manual : 1 copy

 

 
Laminar Flow Apparatus
 

The set up consists of gear pump of size 1” x 1” coupled to 3 HP, 3 phase, 440 V motor. 02332

M.S. Collecting tank & Reservoir tank mounted on strong iron stand.

Necessary pipe line is provided.

Pressure gauge, Vaccum gauge, Switch, Starter, Stop Clock, Energy meter, gate valve to avoid complete closing.

 
 
 

a. MODEL OF TURBINE RUNNERS
i. Pelton (Al) 200 mm dia
ii Francis (Al) 150 mm dia
iii Kaplon (Al) 150 mm dia

b. PUMP IMPELLERS
i. Centrifugal pump (Radial) CI 200 mm dia
ii. Mixed flow (Radial and Axial) – Al 150 mm dia
iii. Self Priming (Tangential) GM 100 mm dia

 
 
Heleshaw Apparatus

Heleshaw Apparatus

The setup is allow the user to visualize the ideal flow around the immersed bodies of different types.

Working Section : Made of two laminated glass / acrylic sheets which are closely spaced and fixed in a leak proof moulding

Flow table : Width = minimum 300mm,
                   Length = minimum 500mm,

Dye Tank With Flow Control : Stainless steel tank with minimum 1L capacity

Dye injection facility Sump Tank : Stainless steel tank with minimum 40L capacity

Water circulation : Suitable capacity pump

Flow control valve and bypass valve to regulate the flow

Obstacles : Different shapes

The whole assembly is housed in a good quality painted structure



 
 
Designed by : MID   Hosted by : GID   Promoted by : PBD